A generic system job specifies one trigger that must meet the all of the following criteria:
The trigger fires when the system job begins, and, because the trigger's Timeout doubles as the job's walltime, both complete at the same time. The job and trigger have the same completion code.
JOBCFG[gen] GENERICSYSJOB=EType=start,AType=exec,Action="$HOME/installVM.py $HOSTLIST",Timeout=1:00:00,Flags=objectxmlstdin
The job template gen creates a job with a walltime of 1 hour.
Sometimes the trigger will set a variable on completion or require a variable to run at all. For information about setting variables, passing them up to parent objects, and requiring variables on parent objects, see the Trigger Variables documentation.
You can attach additional triggers using the TRIGGER attribute and delimit them with semicolons.
JOBCFG[gen] GENERICSYSJOB=<genericSystemJobTriggerSpecs>
JOBCFG[gen] TRIGGER=<triggerSpecs>;TRIGGER=<triggerSpecs>;TRIGGER=<triggerSpecs>